DOD-STD-35-117(MI)
16 June 1978
CHAR
CODE STANDARD
PARAGRAPH
TESTING SHALL BE PERFORMED IN
1814 ENDURANCE, ELECTRICAL.
ACCORDANCE WITH 1814.
1816 THE NUMBER OF OPERATION CYCLES SHALL BE NOT LESS THAN 1816.
1820 THE APPLIED VOLTAGE SHALL BE 1820 VOLTS, AC.
THE APPLIED VOLTAGE SHALL BE 1822 VOLTS, DC.
1822
1824 THE LOAD SHALL BE 1824 PERCENT OF RATED LOAD.
1826 THE LOAD TYPE SHALL BE 1826.
1828 THE TEST CYCLE RATE SHALL BE 1828 CYCLES PER MINUTE.
THE REQUIREMENT(S) SHALL BE IN
1882 ENDURANCE, MECHANICAL.
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1882.
THE REQUIREMENT(S) SHALL BE AS
1883 ENDURANCE,
MECHANCIAL.
FOLLOWS:
1884 ITEM(S) SHALL REMAIN WITHIN SPECIFIED TOLERANCES.
1886 THERE SHALL BE NO EVIDENCE OF MALFUNCTION.
1888 THE CONTACT RESISTANCE SHALL BE NOT GREATER THAN 1888
MILLIOHMS.
TESTING SHALL BE PERFORMED IN
1852 ENDURANCE, MECHANICAL.
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1852.