DOD-STD-35-117(MI)
16 June 1978
CHAR
CODE STANDARD
PARAGRAPH
4862 DIELECTRIC WITHSTANDING VOLTAGE AT SEA LEVEL. TESTING
SHALL BE PERFORMED IN ACCORDANCE WITH METHOD 301 OF
MILSTD202.
TEST VOLTAGE SHALL BE 4854 VOLTS, DC.
4854
TEST VOLTAGE SHALL BE 4855 VOLTS, AC.
4855
POINTS OF APPLICATION OF THE TEST VOLTAGE SHALL BE AS
FOLLOWS:
BETWEEN THE TERMINATIONS TIED TOGETHER AND THE MOUNTING
4842
HARDWARE.
BETWEEN THE TERMINATIONS TIED TOGETHER AND THE CASE.
4848
4844 BETWEEN MUTUALLY INSULATED PARTS.
4845 BETWEEN ALL INSULATED PARTS AND GROUND.
4846 BETWEEN CURRENT CARRYING PARTS AND THE CASE.
SPECIAL PREPARATION OR CONDITIONS SHALL BE IN ACCORDANCE
4850
WITH 4850.
4867 DURATION OF APPLICATION OF TEST VOLTAGE SHALL BE 4867
SECOND(S).
5000 MOUNTING SHALL BE IN ACCORDANCE WITH 5000.
REGULATION OF TEST VOLTAGE SHALL BE WITHIN 4869 PERCENT.
4869
73