DOD-STD-35-117(MI)
16 June 1978
CHAR
CODE STANDARD
PARAGRAPH
POINTS OF APPLICATION OF THE TEST VOLTAGE SHALL BE AS
FOLLOWS:
6311 BETWEEN THE TERMINATIONS TIED TOGETHER AND THE MOUNTING
HARDWARE.
6312 BETWEEN THE TERMINATIONS TIED TOGETHER AND THE CASE.
6292 BETWEEN MUTUALLY INSULATED PARTS.
6293 BETWEEN ALL INSULATED PARTS AND GROUND.
6294 BETWEEN CURRENT CARRYING PARTS AND THE CASE.
SPECIAL PREPARATION SHALL BE IN ACCORDANCE WITH 4859.
4859
4891 DURATION OF APPLICATION OF TEST VOLTAGE SHALL BE 4891
SECOND(S).
6280
MOUNTING SHALL BE IN ACCORDANCE WITH 6280.
6308
REGULATION OF THE TEST VOLTAGE SHALL BE WITHIN 6308 PERCENT.
4900 THE KILOVOLTAMPERE RATING OF HIGH VOLTAGE SOURCE SHALL BE
NOT LESS THAN 4900 KILOVOLTAMPERE(S).