DOD-STD-35-117(MI)
6 June 1978
KEYWORD CODE INDEX (KCI)
CHAR
CHARACTERISTIC NAME
CODE
DIELECTRIC WITHSTANDING VOLTAGE AT REDUCED
BAROMETRIC PRESSURE (CONT)
PER MIL-STD-202, METHOD 301. (CONT)
POINTS OF VOLTAGE APPLICATION:
BETWEEN TERMINATIONS TIED TOGETHER
AND MOUNTING HARDWARE.
BETWEEN TERMINATIONS TIED TOGETHER
AND CASE.
6312
BETWEEN MUTUALLY INSULATED PARTS.
6292
BETWEEN ALL INSULATED PARTS AND GROUND.
6293
BETWEEN CURRENT CARRYING PARTS AND THE
CASE.
6294
SPECIAL PREPARATION PER DOCUMENT (DOC DES)
4859
DURATION OF VOLTAGE APPLICATION (SECONDS)
4891
MOUNTING PER DOCUMENT (DOC DES)
6280
REGULATION OF TEST VOLTAGE (PCT)
6308
MINIMUM KILOVOLTAMPERE RATING OF VOLTAGE
SOURCE (KILOVOLTAMPERES)
4900
68