DOD-STD-35-117(MI)
16 June 1978
CHAR
CODE STANDARD
PARAGRAPH
THE SURGE CURRENT SHALL BE NOT GREATER THAN 4902 AMPERE(S).
4902
THE SURGE CURRENT SHALL BE NOT GREATER THAN 6310
6310
MILLIAMPERE(S).
THE
4874 DIELECTRIC WITHSTANDING VOLTAGE AT SEA LEVEL.
REQUIREMENT(S) SHALL BE IN ACCORDANCE WITH THE BASE
DOCUMENT, EXCEPT 4874.
THERE
4856 DIELECTRIC WITHSTANDING VOLTAGE AT SEA LEVEL.
SHALL BE NO EVIDENCE OF FLASHOVER, MECHANICAL DAMAGE,
ARCING, OR INSULATION BREAKDOWN.
THE LEAKAGE CURRENT SHALL BE NOT GREATER THAN 4875
4875
MILLIAMPERE(S) .
ITEM(S) SHALL REMAIN WITHIN SPECIFIED TOLERANCE.
4847
TESTING
4861 DIELECTRIC WITHSTANDING VOLTAGE AT SEA LEVEL.
SHALL BE PERFORMED IN ACCORDANCE WITH THE BASE DOCUMENT,
EXCEPT 4861.
71