DOD-STD-35-71A(MI)
14 January 1983
CHAR
CODE
STANDARD
PARAGRAPH
POINTS OF APPLICATION OF THE TEST VOLTAGE SHALL BE AS
FOLLOWS.
4969 BETWEEN MUTUALLY INSULATED PARTS.
BETWEEN ALL INSULATED PARTS AND GROUND.
4970
4971 BETWEEN CURRENT CARRYING PARTS AND THE CASE.
BETWEEN CURRENT CARRYING PARTS AND GROUND.
6202
6207 DIELECTRIC WITHSTANDING VOLTAGE TEST SHALL BE
PERFORMED AT HIGH HUMIDITY.
DIELECTRIC WITHSTANDING VOLTAGE TEST SHALL BE
6206
PERFORMED AFTER DRYING.
THE REQUIREMENT(S) SHALL BE IN ACCORDANCE WITH
IMMERSION
4819
THE BASE DOCUMENT, EXCEPT 4819.
IMMERSION. THERE SHALL BE NO EVIDENCE OF PHYSICAL DAMAGE.
4820
INSULATION RESISTANCE AFTER TEST SHALL BE NOT LESS THAN
4825
4825 MEGOHM(S),
75