DOD-STD-35-71A(MI)
14 January 1983
CHAR
STANDARD PARAGRAPH
CODE
TESTING SHALL BE PERFORMED IN ACCORDANCE
FLAME RESPONSE.
1784
WITH THE BASE DOCUMENT, EXCEPT 1784.
TESTING SHALL BE PERFORMED IN ACCORDANCE
FLAME RESPONSE.
1786
WITH MILS24236.
1788 THE FLAME TEMPERATURE SHALL BE 1788 DEGREES CELSIUS.
1790
THE FLAME TEMPERATURE TOLERANCE SHALL BE PLUS OR MINUS
1790 DEGREES CELSIUS.
2230 THE FLAME TEMPERATURE SHALL BE
2230 DEGREES FAHRENHEIT.
2232 THE FLAME TEMPERATURE TOLERANCE SHALL BE PLUS OR MINUS
2232 DEGREES Fahrenheit
1794 THE DURATION OF FLAME APPLICATION TO THE SWITCH SENSING
ELEMENT SHALL BE 1794 SECOND(S).
THE NUMBER OF CYCLES SHALL BE 1796.
1796
THE REQUIREMENT(S) SHALL BE IN ACCORDANCE
4798
HUMIDITY.
WITH THE BASE DOCUMENT, EXCEPT 4798.
THERE SHALL BE NO EVIDENCE OF CORROSION
HUMIDITY.
4799
OR PHYSICAL DAMAGE.
1477 THERE SHALL BE NO EVIDENCE OF ARCING, FLASHOVER, OR
INSULATION BREAKDOWN WHEN DIELECTRIC WITHSTANDING VOLTAGE
IS APPLIED.