DOD-STD-35-71A(MI)
14 January 1983
CHAR
STANDARD PARAGRAPH
CODE
1742
ENDURANCE.
THE REQUIREMENT(S) SHALL BE IN ACCORDANCE
WITH THE BASE DOCUMENT, EXCEPT 1742.
1743
ENDURANCE.
THE REQUIREMENT(S) SHALL BE AS FOLLOWS.
1744 THERE SHALL BE NO INDICATION OF INTERMITTENT SWITCH
OPERATION.
1746 UNITS SHALL CONFORM TO CALIBRATION REQUIREMENTS AFTER
TEST.
1752 THE CHANGE IN SWITCHING POINT SHALL BE NOT GREATER
THAN 1752 DEGREE(S) CELSIUS.
22110 THE CHANGE IN SWITCHING POINT SHALL BE NOT GREATER
THAN 2210 DEGREE(S) FAHRENHEIT.
1756 THE CONTACT RESISTANCE SHALL BE NOT GREATER THAN 1756
MILLIOHM(S) AFTER TEST.
2212 UNITS SHALL CONFORM TO INSULATION RESISTANCE REQUIREMENT(S)
AFTER TEST.
1722
ENDURANCE. TESTING SHALL BE PERFORMED IN ACCORDANCE
WITH THE BASE DOCUMENT, EXCEPT 1722.
1724
ENDURANCE.
TESTING SHALL BE PERFORMED IN ACCORDANCE
wITH 1724.
1726 THE NUMBER OF OPERATING CYCLES SHALL BE 1726.
63