DOD-STD-35-138(MI)
5 January 1979
CHAR
CODE
STANDARD
PARAGRAPH
1828 THERE SHALL BE 1828 ACTIVATION(S) PRIOR TO MEASUREMENT.
1830 THERE SHALL BE 1830 TEST ACTIVATION(S).
1832 THERE SHALL BE 1832 MEASUREMENT(S) PER ACTIVATION.
1834 THE MEASUREMENT ERROR SHALL BE NOT GREATER THAN 1834
PERCENT.
1836 THE METHOD OF CONNECTION SHALL BE 1836.
THE REQUIREMENT(S)
1840 CORONA AT REDUCED BAROMETRIC PRESSURE.
SHALL BE IN ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1840.
THE REQUIREMENT(S)
1880 CORONA AT REDUCED BAROMETRIC PRESSURE.
SHALL BE AS FOLLOWS:
1882 THERE SHALL BE NO EVIDENCE OF CORONA.
1884 THE VOLTAGE AT WHICH CORONA IS CONTINUOUS (CORONA STARTING
VOLTAGE) SHALL BE NOT LESS THAN 1884 VOLT(S).
1881 THE VOLTAGE AT WHICH CORONA DISAPPEARS COMPLETELY (CORONA
EXTINCTION VOLTAGE) SHALL BE NOT LESS THAN 1881 VOLT(S).
1883 THE APPARENT CORONA CHARGE SHALL BE NOT GREATER THAN 1883
PICOCOULOMB(S) AT THE CORONA STARTING VOLTAGE.
1885 THE APPARENT CORONA CHARGE SHALL BE NOT GREATER THAN 1885
1887 PICOCOULOMB(S) AT 1887 VOLT(S).