DOD-STD-35-138(MI)
5 January 1979
KEYWORD CODE INDEX (KCI)
CHAR
CHARACTERISTIC NAME
CODE
DIELECTRIC WITHSTANDING VOLTAGE AT REDUCED
BAROMETRIC PRESSURE (CONT)
PER MIL-STD202, METHOD 301. (CONT)
*ALTITuDE PER METHOD 105 OF MIL-STB-202
*TEST CONDITION (LETTER)
4886
*TEST VOLTAGE (SELECT ONE)
(VOLTS, DC)
4885
(VOLTS, AC)
4849
POINTS OF VOLTAGE APPLICATION:
BETWEEN TERMINATIONS TIED TOGETHER
AND MOUNTING HARDWARE.
6311
BETWEEN TERMINATIONS TIED TOGETHER
AND CASE.
6312
BETWEEN MUTUALLY INSULATED PARTS.
6292
BETWEEN ALL INSULATED PARTS AND GROUND.
6293
BETWEEN CURRENT CARRYING PARTS AND
THE CASE.
6294
OTHER
3240
SPECIAL PREPARATION PER DOCUMENT
(DOC DES)
4859