DOD-STD-35-138(MI)
5 January 1979
CHAR
CODE
STANDARD
PARAGRAPH
3222
CONTACT BOUNCE.
TESTING SHALL BE PERFORMED IN
ACCORDANCE WITH MIL-S-8805.
3224
THE LOAD VOLTAGE SHALL BE 3224 VOLTS, AC.
3226
THE LOAD VOLTAGE SHALL BE 3226 VOLTS, DC.
3228
THE LOAD CURRENT SHALL BE 3228 AMPERE(S).
3230
THE LOAD CURRENT SHALL BE 3230 MILLIAMPERES.
3232
THE ACTUATOR ACTUATION RATE SHALL BE 3232 INCH(S) PER
SECOND.
1800
CONTACT RESISTANCE.
THE REQUIREMENT(S) SHALL BE IN
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1800.
1802
CONTACT RESISTANCE.
THE REQUIREMENT(S) SHALL BE AS
FOLLOWS:
1804
THE CONTACT RESISTANCE SHALL BE NOT GREATER THAN 1804
OHM(S).
1704
THE CONTACT RESISTANCE SHALL BE NOT GREATER THAN 1704
MILLIOHM(S).
57