DOD-STD-35-138(MI)
5 January 1979
CHAR
CODE
STANDARD
PARAGRAPH
1856 CORONA AT REDUCED BAROMETRIC PRESSURE.
TESTING SHALL BE
PERFORMED IN ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1856.
TESTING SHALL BE
1886 CORONA AT REDUCED BAROMETRIC PRESSURE.
PERFORMED IN ACCORDANCE WITH 1886.
1860 ALTITUDE SHALL BE IN ACCORDANCE WITH METHOD 105 OF
MIL-STD-202, TEST CONDITION 1860.
1888 THE TEST VOLTAGE SHALL BE 11888 VOLTS, AC.
1890 THE AC VOLTAGE FREQUENCY SHALL BE 11890 HERTZ.
1892 THE TEST VOLTAGE SHALL BE 1892 VOLTS, DC.
1686 CORONA AT SEA LEVEL.
THE REQUIREMENT(S) SHALL BE IN
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1686.
THE REQUIREMENT(S) SHALL BE AS FOLLOWS:
1842 CORONA AT SEA LEVEL.
1844 THERE SHALL BE NO EVIDENCE OF CORONA.
1846 THE VOLTAGE AT WHICH CORONA IS CONTINUOUS (CORONA STARTING
VOLTAGE) SHALL BE NOT LESS THAN 1846 VOLT(S).
1848 THE VOLTAGE AT WHICH CORONA DISAPPEARS COMPLETELY (CORONA
EXTINCTION VOLTAGE) SHALL BE NOT LESS THAN 1848 VOLT(S).
1850 THE APPARENT CORONA CHARGE SHALL BE NOT GREATER THAN
1850 PICOCOULOMB(S) AT THE CORONA STARTING VOLTAGE.