CHAR
CODE
STANDARD
PARAGRAPH
2274 THE CONTACT RESISTANCE SHALL BE NOT GREATER THAN 2274
MILLIOHM(S) EITHER DURING OR AFTER TEST.
2276
THE ALLOWABLE TEMPERATURE TOLERANCE DURING AND AFTER
TEST SHALL BE THE INITIAL TEMPERATE TOLERANCE AND AN
ADDITIONAL PLUS OR MINUS 2276 DEGREE(S) CELSIUS.
2278 THE ALLOWABLE TEMPERATURE TOLERANCE DURING AND AFTER
TEST SHALL BE THE INITIAL TEMPERATURE TOLERANCE AND AN
ADDITIONAL PLUS OR MUNUS 2278 DEGREE(S) FAHRENHEIT.
2280
LOW LEVEL Switching
TESTING SHALL BE PERFORMED IN
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 2280.
2282
LOW LEVEL SWITCHING.
TESTING SHALL BE PERFORMED IN
ACCORDANCE WITH METHOD 311 OF MIL-STD-202,
2284 THE NUMBER OF TEST CYCLES SHALL BE 2284.
2286 CYCLING RATE SHALL BE NOT GREATER THAN 2286 CYCLES PER
MINUTE.
2288 MONITORING OF CONTACTS FOR STICKING SHALL NOT BE
APPLICABLE.
1400
MOISTURE RESISTANCE.
THE REQUIREMENT(S) SHALL BE IN
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1400.
87