DOD-STD-35-71A(MI)
14 January 1983
CHAR
STANDARD PARAGRAPH
CODE
2144 A TORQUE OF 2144 POUNDFEET SHALL BE APPLIED IN THE
DIRECTION OF CONNECTOR MATING ROTATION.
A TORQUE OF 2146 NEWTON METER(S) SHALL BE APPLIED IN
2146
THE DIRECTION OF CONNECTOR MATING ROTATION.
2148 DURATION OF TORQUE APPLICATION SHALL BE 2148 MINUTE(S).
THE REQUIREMENT(S) SHALL BE IN
1688 CONTACT RESISTANCE.
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1688.
1690 CONTACT RESISTANCE.
THE CONTACT RESISTANCE SHALL BE
NOT GREATER THAN 1690 MILLIOHM(S).
2150 CONTACT RESISTANCE.
THE CONTACT RESISTANCE SHALL BE
NOT GREATER THAN 2150 OHM(S).
TESTING SHALL BE PERFORMED IN
1672 CONTACT RESISTANCE.
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1672.
1673 CONTACT RESISTANCE.
TESTING SHALL BE PERFORMED IN
ACCORDANCE WITH MIL-STD202, METHOD 3070
1674 THE TEST CURRENT SHALL BE NOT GREATER THAN 1674
AMPERE(S).
1676 THE OPEN CIRCUIT VOLTAGE SHALL BE NOT GREATER THAN
1676 VOLTS DC.