DOD-STD-35-71A(MI)
14 January 1983
CHAR
CODE
STANDARD
PARAGRAPH
1549 TEST CONDITION LETTER 1549 IN ACCORDANCE WITH METHOD 310
OF MILSTD202 SHALL APPLY.
1668
CALIBRATION.
THE REQUIREMENT(S) SHALL BE IN
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1668.
CALIBRATION.
THE CALIBRATION PARAMETERS SHALL BE IN
ACCORDANCE WITH THE VALUES SPECIFIED IN THE
CALIBRATION TABLE.
CALIBRATION TABLE
DEGREES DEGREES
SWITCHING POINT
F
C
OPEN ON INCREASING TEMPERATURE
4125
4100
OPEN ON INCREASING TEMPERATURE TOLERANCE (PLUS)
4101
4126
4102
4127
OPEN ON INCREASING TEMPERATURE TOLERANCE (MINUS)
OPEN ON DECREASING TEMPERATURE
4103
4128
OPEN ON DECREASING TEMPERATURE TOLERANCE (PLUS)
4104
4129
OPEN ON DECREASING TEMPERATURE TOLERANCE (MINUS)
4105
4130
CLOSE ON INCREASING TEMPERATURE
4106
4131
4107
CLOSE ON INCREASING TEMPERATURE TOLERANCE (PLUS)
4132
4108
CLOSE ON INCREASING TEMPERATURE TOLERANCE (MINUS)
4133
CLOSE ON DECREASING TEMPERATURE
4109
4134
4110
CLOSE ON DECREASING TEMPERATURE TOLERANCE (PLUS)
4135
CLOSE ON DECREASING TEMPERATURE TOLERANCE (MINUS)
4111
4136
4112
OPENING TEMPERATURE
4137
4113
OPENING TEMPERATURE TOLERANCE (PLUS)
4138
OPENING TEMPERATURE TOLERANCE (MINUS)
4114
4139
4115
CLOSING TEMPERATURE
4140
39