DOD-STD-35-71A(NI)
14 January 1983
CHAR
CODE
STANDARD
PARAGRAPH
2160 CURRENT CAPACITY.
THE REQUIREMENT(S) SHALL BE IN
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 2160.
2162 CURRENT CAPACITY.
THE REQUIREMENT(S) SHALL BE AS
FOLLOWS.
2164 THE VOLTAGE DROP FOR CIRCUIT 1 SHALL BE NOT GREATER
THAN 2164 VOLT(S).
2166 THE VOLTAGE DROP FOR CIRCUIT 1 SHALL BE NOT GREATER
THAN 2166 MILLIVOLT(S).
2168 THE VOLTAGE DROP FOR CIRCUIT 2 SHALL BE NOT GREATER
THAN 2168 VOLT(S).
2170 THE VOLTAGE DROP FOR CIRCUIT 2 SHALL BE NOT GREATER
THAN 2170 MILLIVOLT(S).
2172 THE VOLTAGE DROP FOR CIRCUIT 3 SHALL BE NOT GREATER
THAN 2172 VOLT(S).
2174 THE VOLTAGE DROP FOR CIRCUIT 3 SHALL BE NOT GREATER
THAN 2174 MILLIVOLT(S).
2176 THE VOLTAGE DROP FOR CIRCUIT 4 SHALL BE NOT GREATER
THAN 2176 VOLT(S).
2178 THE VOLTAGE DROP FOR CIRCUIT 4 SHALL BE NOT GREATER
THAN 2178 MILLIVOLT(S).