DOD-STD-35-71A(MI)
14 January 1983
CHAR
CODE
STANDARD PARAGRAPH
2744 THE OPENING OF CLOSED CONTACTS SHALL BE NOT GREATER THAN
2744 MICROSECOND(S).
2746 THE OPENING OF CLOSED CONTACTS SHALL BE NOT GREATER THAN
2746 MILLISECOND(S).
2748 UNITS SHALL CONFORM TO CALIBRATION REQUIREMENTS AFTER TEST.
2750 THE CHANGE IN SWITCHING POINT SHALL BE NOT GREATER THAN 2750
DEGREE(S) CELSIUS.
2752
THE CHANGE IN SWITCHING POINT SHALL BE NOT GREATER THAN 2752
DEGREE(S) FAHRENHEIT.
1466
VIBRATION, LOW FREQUENCY.
TESTING SHALL BE PERFORMED
IN ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1466.
1467
VIBRATION, LOW FREQUENCY. TESTING SHALL BE PERFORMED
IN ACCORDANCE WITH METHOD 201 OF MIL-STD202.
1470 DURATION OF TEST SHALL BE 1470 HOUR(S) PER AXIS.
4731 MOUNTING SHALL BE BY ANY SUITABLE METHOD.
4730 MOUNTING SHALL BE BY THE NORMAL METHOD.
4729 MOUNTING SHALL BE IN ACCORDANCE WITH 4729.