DOD-STD-35-71A(MI)
14 January 1983
CHAR
CODE
STANDARD
PARAGRAPH
1427 VIBRATION, RANDOM.
TESTING SHALL BE PERFORMED IN
ACCORDANCE WITH METHOD 214 OF MIL-STD-202.
1428 TEST CONDITION NUMBER AND LETTER 1428 SHALL APPLY.
1438 THE DURATION OF THE TEST SHALL BE 1438 MINUTE(S).
1431 THE DURATION OF THE TEST SHALL BE 1431 HOUR(S).
1452 THE MONITORING INSTRUMENTATION OF THE VIBRATION EXCITATION
SHALL BE ANY SUITABLE INSTRUMENTATION SYSTEM.
1453 THE MONITORING INSTRUMENTATION OF THE VIBRATION EXCITATION
SHALL BE A CALIBRATED AC TO DC CONVERTER AND STRIP CHART
RECOR ER.
1459
THE MONITORING INSTRUMENTATION OF THE VIBRATION EXCITATION
SHALL BE A CLAIBRATED OSCILLOSCOPE.
1430 THERE SHALL BE 1430 VIBRATION MONITORING POINT(S).
1439 THE LOCATION OF VIBRATION MONITORING POINTS SHALL BE ANY
SUITABLE LOCATION,