DOD-STD-35-71A(MI)
14 January 1983
CHAR
CODE
STANDARD
PARAGRAPH
1414 TEST SPECIMENS SHALL BE SUBJECTED TO TEST CONDITION D.
1416
TEST SPECIMENS SHALL BE SUBJECTED TO TEST CONDITION
E. THE TORQUE SHALL BE 1416 POUNDINCH(S).
1421
TEST SPECIMENS SHALL BE SUBJECTED TO TEST CONDITION
THE TORQUE SHALL BE 1421 NEWTON METER(S).
E.
THERMAL SHOCK (TEMPERATURE CYCLING). THE REQUIREMENT(S)
4722
SHALL BE IN ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 4722.
4723 THERMAL SHOCK (TEMPERATURE CYCLING).
THERE SHALL BE NO
EVIDENCE OF PHYSICAL DAMAGE.
2710 UNITS SHALL CONFORM TO CALIBRATION REQUIREMENTS AFTER TEST.
2712
THE CHANGE IN SWITCHING POINT SHALL BE NOT GREATER THAN
2712 DEGREE(S) CELSIUS.
2714 THE CHANGE IN SWITCHING POINT SHALL BE NOT GREATER THAN 2714
DEGREE(S) FAHRENHEIT.
4713 THERMAL SHOCK (TEMPERATURE CYCLING).
TESTING SHALL BE
PERFORMED IN ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 4713.