DOD-STD-35-71A(MI)
14 January 1983
CHAR
CODE STANDARD
PARAGRAPH
1436 VIBRATION, RANDOM.
THERE SHALL BE NO EVIDENCE OF PHYSICAL
DAMAGE.
2760 THE CLOSING OF OPEN CONTACTS SHALL BE NOT GREATER THAN
2760 MICROSECOND(S).
2762
THE CLOSING OF OPEN CONTACTS SHALL BE NOT GREATER THAN
2762 MILLISECOND(S).
2764 THE OPENING OF CLOSED CONTACTS SHALL BE NOT GREATER
THAN 2764 MICROSECOND(S).
2766 THE OPENING OF CLOSED CONTACTS SHALL BE NOT GREATER
THAN 2766 MILLISECOND(S).
2768 UNITS SHALL CONFORM TO CALIBRATION REQUIREMENTS AFTER
TEST.
2770 THE CHANGE IN SWITCHING POINT SHALL BE NOT GREATER
THAN 2770 DEGREE(S) CELSIUS.
2772 THE CHANGE IN SWITCHING POINT SHALL BE NOT GREATER THAN
2772 DEGREE(S) FAHREHEIT.
1426 VIBRATION, RANDOM.
TESTING SHALL BE PERFORMED IN ACCORDANCE
WITH THE BASE DOCUMENT, EXCEPT 1426.
161