DOD-STD-35-37A(MI)
15 December 1978
CHAR
CODE STANDARD PARAGRAPH
4844 BETWEEN MUTUALLY INSULATED PARTS.
4845 BETWEEN ALL INSULATED PARTS AND GROUND.
4846 BETWEEN CURRENT CARRYING PARTS AND THE CASE.
4867 DURATION OF APPLICATION OF TEST VOLTAGE SHALL BE 4867
SECOND(S).
4869 REGULATION OF TEST VOLTAGE SHALL BE WITHIN 4869 PERCENT.
4870 THE KILOVOLTAMPERE RATING OF HIGH VOLTAGE SOURCE SHALL
BE NOT LESS THAN 4870 KILOVOLTAMPERE(S).
4717 THE SURGE CURRENT SHALL BE NOT GREATER THAN 4717 AMPERE(S).
THE SURGE CURRENT SHALL BE NOT GREATER THAN 4897
4897
MILLIAMPERE(S),
THE REQUIREMENT(S) SHALL
2 3 7 1 EFFECTIVE PARALLEL RESISTANCE.
BE IN ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 2371.
THE EFFECTIVE PARALLEL
2 3 7 2 EFFECTIVE PARALLEL RESISTANCE.
R E S I S T A N C E SHALL BE 2372 KILOHM(S).
TESTING SHALL BE PERFORMED
2 3 7 5 EFFECTIVE PARALLEL RESISTANCE.
IN ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 2375.
57