DOD-STD-35-37A(MI)
15 December 1978
CHAR
STANDARD PARAGRAPH
CODE
4901
ITEM(S) SHALL REMAIN WITHIN SPECIFIED TOLERANCE.
4884 DIELECTRIC WITHSTANDING VOLTAGE AT REDUCED BAROMETRIC
TESTING SHALL BE PERFORMED IN ACCORDANCE
PRESSURE.
WITH THE BASE DOCUMENT, EXCEPT 4884.
6300
DIELECTRIC WITHSTANDING VOLTAGE AT REDUCED BAROMETRIC
PRESSURE.
TESTING SHALL BE PERFORMED IN ACCORDANCE
W I T H METHOD 301 OF MILSTD-202.
4886 ALTITUDE SHALL BE IN ACCORDANCE WITH TEST CONDITION
L E T T E R 4886 OF METHOD 105 OF MILSTD-202.
TEST VOLTAGE SHALL BE 4885 VOLTS, DC.
4885
4 8 4 9 TEST VOLTAGE SHALL BE 4849 VOLTS, AC.
POINTS OF APPLICATION OF THE TEST VOLTAGE SHALL BE AS
FOLLOWS:
6311 BETWEEN THE TERMINATIONS TIED TOGETHER AND THE MOUNTING
HARDWARE.
6312 BETWEEN THE TERMINATIONS TIED TOGETHER AND THE CASE.
6292 BETWEEN MUTUALLY INSULATED PARTS.
51