DOD-STD-35-37A(MI)
15 December 1978
CHAR
CODE STANDARD PARAGRAPH
6293 BETWEEN ALL INSULATED PARTS AND GROUND.
6294 BETWEEN CURRENT CARRYING PARTS AND THE CASE.
4891 DURATION OF APPLICATION OF TEST VOLTAGE SHALL BE 4 8 9 1
SECOND(S).
REGULATION OF THE TEST VOLTAGE SHALL BE WITHIN 6 3 0 8
6308
PERCENT.
THE KILOVOLTAMPERE RATING OF HIGH VOLTAGE SOURCE SHALL
4900
BE NOT LESS, THAN 4900 KILOVOLTAMPERE (S).
THE SURGE CURRENT SHALL BE NOT GREATER THAN 4 9 0 2 AMPERE(S).
4902
THE SURGE CURRENT SHALL BE NOT GREATER THAN 6 3 1 0
6310
MILLIAMPERE(S).
THE
4874 DIELECTRIC WITHSTANDING VOLTAGE AT SEA LEVEL.
REQUIREMENT(S) SHALL BE IN ACCORDANCE WITH THE BASE
DOCUMENT, EXCEPT 4874.
THERE
4856 DIELECTRIC WITHSTANDING VOLTAGE AT SEA LEVEL.
SHALL BE NO EVIDENCE OF FLASHOVER, MECHANICAL DAMAGE,
ARCING, OR INSULATION BREAKDOWN.