DOD-STD-35-37A(MI)
15 December 1978
KEYWORD CODE INDEX (KCI)
CHAR
CHARACTERISTIC NAME
CODE
DIELECTRIC WITHSTANDING VOLTAGE AT REDUCED
BAROMETRIC PRESSURE (CONT)
NO EVIDENCE OF FLASHOVER, MECHANICAL
DAMAGE, ARCING, OR INSULATION BREAKDOWN. (CONT)
REMAIN WITHIN SPECIFIED TOLERANCE.
4901
TEST METHODS (SELECT ONE)
PER BASE DOCUMENT EXCEPT
4884
P E R MIL-STD-202, METHOD 301.
6300
*ALTITUDE PER METHOD 105 OF MILSTD202
*TEST CONDITION (LETTER)
4886
*TEST VOLTAGE (SELECT ONE)
( V O L T S , DC)
4885
( V O L T S , AC)
4849
POINTS OF VOLTAGE APPLICATION:
BETWEEN TERMINATIONS TIED TOGETHER
AND MOUNTING HARDWARE.
6311
BETWEEN TERMINATIONS TIED TOGETHER
AND CASE.
6312
BETWEEN MUTUALLY INSULATED PARTS.
6292