DOD-STD-35-85A(MI)
1 December 1978
CHAR
CODE
STANDARD
PARAGRAPH
POINTS OF APPLICATION OF THE TEST VOLTAGE SHALL BE AS
FOLLOWS:
4969 BETWEEN MUTUALLY INSULATED PARTS.
4970 BETWEEN ALL INSULATED PARTS AND GROUND.
4971 BETWEEN CURRENT CARRYING PARTS AND THE CASE.
6202 BETWEEN CURRENT CARRYING PARTS AND GROUND.
6207 DIELECTRIC WITHSTANDING VOLTAGE TEST SHALL BE PERFORMED
AT HIGH HUMIDITY.
6206 DIELECTRIC WITHSTANDING VOLTAGE TEST SHALL BE PERFORMED
AFTER DRYING.
THE REQUIREMENT(S) SHALL BE IN
1380
INSULATION RESISTANCE.
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1380.
THE REQUIREMENT(S) SHALL BE AS
6359
INSULATION
RESISTANCE.
FOLLOWS:
69