2037 HOUSING WIND TEST.
THE REQUIREMENT(S) SHALL BE AS FOLLOWS:
2038 THERE SHALL BE NO DISTORTION OR DAMAGE.
TESTING SHALL BE PERFORMED IN
2022 HOUSING WIND TEST.
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 2022.
TESTING SHALL BE PERFORMED IN
2024 HOUSING WIND TEST.
ACCORDANCE WITH MIL-F-16081.
2026 THE WIND VELOCITY SHALL BE NOT LESS THAN 2026 MILES PER
HOUR.
2028 THE WIND VELOCITY SHALL BE NOT LESS THAN 2028 KILOMETERS
PER HOUR.
2030 THE WIND VELOCITY SHALL BE NOT LESS THAN 2030 METERS PER
SECOND.
4798
HUMIDITY.
THE REQUIREMENT(S) SHALL BE IN ACCORDANCE WITH
THE BASE DOCUMENT, EXCEPT 4798.
4799
HUMIDITY.
THERE SHALL BE NO EVIDENCE OF CORROSION OR
PHYSICAL DAMAGE.
2050 THE TIME REQUIRED FOR ATTAINMENT OF RATED SPEED SHALL BE
NOT GREATER THAN 2050 SECOND(S).