DOD-STD-35-85A(MI)
1 December 1978
CHAR
CODE
STANDARD
PARAGRAPH
THERE SHALL BE NO EVIDENCE OF
1396
MOISTURE RESISTANCE.
CORROSION OR PHYSICAL DAMAGE.
1398 ITEM(S) SHALL REMAIN WITHIN SPECIFIED TOLERANCE.
1394 THERE SHALL BE NO EVIDENCE OF FLASHOVER, MECHANICAL
DAMAGE, ARCING OR INSULATION BREAKDOWN, WHEN DIELECTRIC
WITHSTANDING VOLTAGE IS APPLIED.
1429 CURRENT LEAKAGE SHALL BE NOT GREATER THAN 1429
MILLIAMPERE(S) AT HIGH HUMIDITY.
1404 CURRENT LEAKAGE SHALL BE NOT GREATER THAN 1404
MILLIAMPERE(S) AFTER DRYING.
1432 INSULATION RESISTANCE SHALL BE NOT LESS THAN 1432
MEGOHM(S) AT HIGH HUMIDITY.
1406 INSULATION RESISTANCE SHALL BE NOT LESS THAN 1406
MEGOHM(S) AFTER DRYING.
MEASUREMENTS BEFORE TEST-SHALL BE AS FOLLOWS.
2501 OPERATING CURRENT SHALL BE 2501 AMPERES.
2507 SPEED WITH LOAD SHALL BE 2507 REVOLUTIONS PER MINUTE.
2505 SPEED WITHOUT LOAD SHALL BE 2505 REVOLUTIONS PER MINUTE.
2503 THE INSULATION RESISTANCE SHALL BE NOT LESS THAN 2503
MEGOHM(S).