DOD-STD-35-71A(MI)
14 January 1983
CHAR
CODE
STANDARD
PARAGRAPH
2304 SWITCHES SHALL BE OPERABLE AFTER TEST.
2306 MOUNTING TORQUE. TESTING SHALL BE PERFORMED IN
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 2306.
2308 MOUNTING TORQUE.
TESTING SHALL BE PERFORMED IN
ACCORDANCE WITH MILS24236.
2310 A TORQUE OF 2310 POUNDFEET SHALL BE APPLIED.
2312 A TORQUE OF 2312 NEWTON METER(S) SHALL BE APPLIED.
2314 DURATION OF TORQUE APPLICATION SHALL BE NOT LESS THAN
2314 MINUTE(S).
1858
OVERLOAD.
THE REQUIREMENT(S) SHALL BE IN ACCORDANCE
WITH THE BASE DOCUMENT, EXCEPT 1858.
2320
OVERLOAD.
THE REQUIREMENTS SHALL BE AS FOLLOWS.
2322 THERE SHALL BE NO EVIDENCE OF STICKING OR WELDING OF
CONTACTS.
1860 THERE SHALL BE NO EVIDENCE OF MECHANICAL OR ELECTRICAL
FAILURE.
1862
THE CONTACT RESISTANCE AFTER TEST SHALL BE NOT GREATER
THAN 1862 MILLIOHM(S).