DOD-STD-35-138(MI)
5 January 1979
CHAR
CODE
STANDARD
PARAGRAPH
2266 CONTACTS SHALL BE MONITORED FOR STICKING.
2268 THERE SHALL BE 2268 TEST CYCLES.
2270 THE TEST CYCLE RATE SHALL BE 2270 CYCLES PER MINUTE.
2272 THE PLUS CYCLE RATE TOLERANCE SHALL BE 2272 CYCLES PER
MINUTE.
2274 THE MINUS CYCLE RATE TOLERANCE SHALL BE 2274 CYCLES PER
MINUTE.
3284 THE TEST TEMPERATURE SHALL BE 3284 DEGREES CELSIUS.
THE REQUIREMENT(S) SHALL BE IN
1400
MOISTURE RESISTANCE.
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1400.
THERE SHALL BE NO EVIDENCE OF
1396
MOISTURE RESISTANCE.
CORROSION OR PHYSICAL DAMAGE.
1398
ITEM(S) SHALL REMAIN WITHIN SPECIFIED TOLERANCE.
1394
THERE SHALL BE NO EVIDENCE OF FLASHOVER, MECHANICAL
DAMAGE, ARCING OR INSULATION BREAKDOWN, WHEN DIELECTRIC
WITHSTANDING VOLTAGE IS APPLIED.
1429 CURRENT LEAKAGE SHALL BE NOT GREATER THAN 3429
MILLIAMPERE(S) AT HIGH HUMIDITY.
.
.