DOD-STD-35-138(MI)
5 January 1979
CHAR
STANDARD
PARAGRAPH
CODE
2200 LIFE, LOW LEVEL SWITCHING AT REDUCED BAROMETRIC' PRESSURE.
TESTING SHALL BE PERFORMED IN ACCORDANCE WITH THE BASE
DOCUMENT? EXCEPT 2200.
LIFE, LOW LEVEL SWITCHING AT REDUCED BAROMETRIC PRESSURE.
2202
TESTING SHALL BE PERFORMED IN ACCORDANCE WITH METHOD
311 OF MIL-STD-202.
2204 ALTITUDE SHALL BE IN ACCORDANCE WITH METHOD 105 OF
MIL-STD-202, TEST CONDITION 2204.
THE LOAD CURRENT SHALL BE NOT GREATER THAN 2208
2208
MILLIAMPERE(S).
2206 THE LOAD CURRENT SHALL BE NOT GREATER THAN 2206
AMPERE(S).
2210 THE LOAD VOLTAGE SHALL BE NOT GREATER THAN 2210
VOLT(S), DC.
THE LOAD VOLTAGE SHALL BE NOT GREATER THAN 2212
2212
MILLIVOLTS, DC.
2214 THE LOAD VOLTAGE SHALL BE NOT GREATER THAN 2214
VOLT(S), AC.
2216 THE LOAD VOLTAGE SHALL BE NOT GREATER THAN 2216
MILLIVOLTS, AC.
2218 CONTACTS SHALL BE MONITORED FOR STICKING.
107
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business