CHAR
CODE
STANDARD
PARAGRAPH
4985 STEP 7A OF METHOD 106 OF MIL-STD-202 IS NOT APPLICABLE.
4986 STEP 7B OF METHOD 106 OF MIL-STD-202 IS NOT APPLICABLE.
1449 MOUNTING SHALL BE IN ACCORDANCE WITH 1449.
4983 PERFORM DIELECTRIC WITHSTANDING VOLTAGE TEST AT HIGH
HUMIDITY.
4984 PERFORM DIELECTRIC WITHSTANDING VOLTAGE TEST AFTER DRYING.
2320
OPERATING CHARACTERISTICS.
THE REQUIREMENT(S) SHALL BE
IN ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 2320.
2322
OPERATING CHARACTERISTICS.
THE REQUIREMENT(S) SHALL BE
AS FOLLOWS:
2328 THE ACTUATING/OPERATING FORCE SHALL BE NOT LESS THAN 2328
NEWTON(S).
2332 THE ACTUATING/OPERATING FORCE SHALL BE NOT LESS THAN 2332
OUNCE(S),
2334 THE ACTUATING/OPERATING FORCE SHALL BE NOT LESS THAN 2334
POUND(S).