DOD-STD-35-85A(MI)
1 December 1978
.
CHAR
CODE
STANDARD
PARAGRAPH
4861 DIELECTRIC WITHSTANDING VOLTAGE AT SEA LEVEL.
TESTING
SHALL BE PERFORMED IN ACCORDANCE WITH THE BASE DOCUMENT,
EXCEPT 4861.
4862 DIELECTRIC WITHSTANDING VOLTAGE AT SEA LEVEL.
TESTING
SHALL BE PERFORMED IN ACCORDANCE WITH METHOD 301 OF
MIL-STD-202.
4854 TEST VOLTAGE SHALL BE 4854 VOLTS, DC.
4855 TEST VOLTAGE SHALL BE 4855 VOLTS, AC.
POINTS OF APPLICATION OF THE TEST VOLTAGE SHALL BE AS
FOLLOWS:
4844 BETWEEN MUTUALLY INSULATED PARTS.
4845 BETWEEN ALL INSULATED PARTS AND GROUND.
4846 BETWEEN CURRENT CARRYING PARTS AND THE CASE.
4867 DURATION OF APPLICATION OF TEST VOLTAGE SHALL BE 4867
SECOND(S).
4717 THE SURGE CURRENT SHALL BE NOT GREATER THAN 4717 AMPERE(S).
4897 THE SURGE CURRENT SHALL BE NOT GREATER THAN 4897
MILLIAMPERE(S).
6267
METHOD OF CONNECTION OF
TEST
VOLTAGE
SHALL
BE
IN
ACCORDANCE WITH 6267.