DOD-STD-35-85A(MI)
1 December 1978
CHAR
CODE
STANDARD
PARAGRAPH
DIELECTRIC WITHSTANDING VOLTAGE AT REDUCED BAROMETRIC
4906
THERE SHALL BE NO EVIDENCE OF FLASHOVER,
PRESSURES
MECHANICAL DAMAGE, ARCING, OR INSULATION BREAKDOWN.
THE LEAKAGE CURRENT SHALL BE NOT GREATER THAN 4894
4894
MILLIAMPERE(S),
ITEM(S) SHALL REMAIN WITHIN SPECIFIED TOLERANCE*
4901
DIELECTRIC WITHSTANDING VOLTAGE AT REDUCED BAROMETRIC
4884
TESTING SHALL BE PERFORMED IN ACCORDANCE
PRESSURE.
WITH THE BASE DOCUMENT, EXCEPT 4884.
DIELECTRIC WITHSTANDING VOLTAGE AT REDUCED BAROMETRIC
6300
TESTING SHALL BE PERFORMED IN ACCORDANCE
PRESSURE.
WITH METHOD 301 OF MIL-STD-202.
ALTITUDE SHALL BE IN ACCORDANCE WITH TEST CONDITION
4886
LETTER 4886 OF METHOD 105 OF MIL-STD-202.
TEST VOLTAGE SHALL BE 4885 VOLTS, DC6
4885
TEST VOLTAGE SHALL BE 4849 VOLTS, AC.
4849
49