DOD-STD-35-36B(MI)
20 February 1979
CHAR
CODE
STANDARD
PARAGRAPH
PERFORMANCE, HIGH TEMPERATURE.
TESTING SHALL BE PERFORMED
3535
IN ACCORDANCE WITH MIL-P-25732.
3536 TEST PRESSURE SHALL BE 3536 POUNDS PER SQUARE INCH.
3538 TEST PRESSURE TOLERANCE SHALL BE 3538 POUNDS PER SQUARE
--.
INCH.
3541 TEST PRESSURE SHALL BE 3541 KILOPASCALS.
3543 TEST PRESSURE TOLERANCE SHALL BE 3543 KILOPASCALS.
3548 TEST TEMPERATURE SHALL BE 3548 DEGREES CELSIUS.
3551 TEST TEMPERATURE TOLERANCE SHALL BE 3551 DEGREES CELSIUS.
3554 THE TEST TEMPERATURE SHALL BE REACHED WITHIN 3554 MINUTE(S).
3556 THE TEST DURATION SHALL BE 3556 HOUR(S).
2582 PERFORMANCE? LOW TEMPERATURE. THE REQUIREMENT(S) SHALL BE
IN ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 2582.
2584 PERFORMANCE? LOW TEMPERATURE. THE TOTAL LEAKAGE DURING
THE ENTIRE TEST SHALL BE NOT GREATER THAN 2584 CUBIC
CENTIMETERS FROM EACH GLAND.