DOD-STD-35-36B(MI)
20 February 1979
CHAR
CODE STANDARD PARAGRAPH
FRICTION TORQUE SHALL BE 1818 POUND-INCH AT ROOM
TEMPERATURE.
FRICTION TORQUE SHALL BE 1820 NEWTON-METER AT ROOM
TEMPERATURE.
FRICTION TORQUE SHALL BE 1822 POUND-INCH AT LOW TEMPERATURE.
1822
FRICTION TORQUE SHALL BE 1824 NEWTON-METER AT LOW
1824
TEMPERATURE.
FRICTION TORQUE. TESTING SHALL BE PERFORMED IN ACCORDANCE
1802
WITH THE BASE DOCUMENT. EXCEPT 1802.
1804
FRICTION TORQUE. TESTING SHALL BE PERFORMED IN ACCORDANCE
WITH MIL-S-21558.
ROOM TEMPERATURE SHALL BE 1806 DEGREES CELSIUS.
1806
ROOM TEMPERATURE TOLERANCE SHALL BE 1808 DEGREES CELSIUS.
1808
LOW TEMPERATURE SHALL BE 1810 DEGREES CELSIUS.
1810
LOW TEMPERATURE TOLERANCE SHALL BE 1812 DEGREES CELSIUS.
1812
109