DOD-STD-35-138(MI)
5 January 1979
CHAR
CODE
STANDARD
PARAGRAPH
3610
ENDURANCE, MECHANICAL.
TESTING SHALL BE PERFORMED IN
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 3610.
3612
ENDURANCE,
Mechanical
TESTING SHALL BE PERFORMED IN
ACCORDANCE WITH 3612.
3614 THERE SHALL BE 3614 OPERATING CYCLES.
3616 THE TEST CYCLE RATE SHALL BE 3616 CYCLES PER MINUTE,
3254 THE TEST TEMPERATURE SHALL BE 3254 DEGREES CELSIUS.
3256 CONTACT MONITORING SHALL BE 3256.
1680
Explosion
THE REQUIREMENT(S) SHALL BE IN ACCORDANCE WITH
THE BASE DOCUMENT, EXCEPT 1680.
-
1928
Explosion
THE REQUIREMENT(S) SHALL BE AS FOLLOWS:
1930 SWITCHES SHALL BE ELECTRICALLY AND MECHANICALLY OPERATIVE
AFTER TEST.
1932 THERE SHALL BE NO EXPLOSION WITHIN THE SWITCH OR CHAMBER.
1934 THERE SHALL BE NO EXPLOSION IN THE CHAMBER WHETHER OR NOT
EXPLOSION OCCURS IN THE SWITCH.