DOD-STD-35-138(MI)
5 January 1979
CHAR
CODE
STANDARD
PARAGRAPH
3264 THE ITEM(S) SHALL REMAIN ELECTRICALLY AND MECHANICALLY
OPERATIVE.
3266 THE DURATION BETWEEN RELEASE OF ACTUATOR AND OPENING OF
NORMALLY OPEN CONTACTS SHALL BE NOT GREATER THAN 3266
SECOND(S).
3268 THE DURATION BETWEEN RELEASE OF ACTUATOR AND CLOSING OF
NORMALLY CLOSED CONTACTS SHALL BE NOT GREATER THAN 3268
Second
TESTING SHALL BE PERFORMED IN ACCORDANCE WITH
ICINGo
3270
THE BASE DOCUMENT, EXCEPT 3270.
TESTING SHALL BE PERFORMED IN ACCORDANCE WITH
3272
ICING.
MIL-S-8805.
3274 THERE SHALL BE 3274 CYCLE(S) OF OPERATION.
THE REQUIREMENT(S) SHALL BE IN ACCORDANCE WITH
4819
IMMERSION.
THE BASE DOCUMENT. EXCEPT 4819.
THERE SHALL BE NO EVIDENCE OF PHYSICAL DAMAGE.
4820
IMMERSION.
93