DOD-STD-35-138(MI)
5 January 1979
CHAR
CODE
STANDARD
PARAGRAPH
l502
SHOCK, SPECIFIED PULSE.
TESTING SHALL BE PERFORMED IN
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1502.
1500
SHOCK, SPECIFIED PULSE.
TESTING SHALL BE PERFORMED IN
ACCORDANCE WITH METHOD 213 OF MIL-STD-202.
1504 TEST CONDITION LETTER 1504 SHALL APPLY.
4686 MOUNTING SHALL BE BY ANY SUITABLE METHOD.
4685 MOUNTING SHALL BE BY THE NORMAL METHOD.
4684 MOUNTING SHALL BE IN ACCORDANCE WITH 46840
1503 MONITORING DURING TEST SHALL BE IN ACCORDANCE WITH METHOD
310 OF MIL-STD-202.
TEST CIRCUIT 1503 SHALL APPLY.
1499 TEST CONDITION LETTER 3499 OF METHOD OF MIL-STD-202
SHALL APPLY.
6204 THE ELECTRICAL LOAD SHALL BE 6204 PERCENT OF THE RATED
LOAD.
2384
SHORT CIRCUIT.
THE REQUIREMENT(S) SHALL BE IN ACCORDANCE
WITH THE BASE DOCUMENT, EXCEPT 2384.