DOD-STD-35-117(MI)
16 June 1978
CHAR
CODE STANDARD
PARAGRAPH
1704 THE ALLOWABLE MEDIA LEAKAGE SHALL BE NOT GREATER THAN 1704
CUBIC CENTIMETERS PER MINUTE.
1706 THE ALLOWABLE MEDIA LEAKAGE SHALL BE NOT GREATER THAN 1706
MICRON CUBIC FOOT PER HOUR AT ONE ATMOSPHERE.
THE REQUIREMENT(S) SHALL BE IN ACCORDANCE
6272 ACCELERATION.
WITH THE BASE DOCUMENT, EXCEPT 6272.
THERE SHALL BE NO EVIDENCE OF PHYSICAL DAMAGE.
6273 ACCELERATION.
7345 THERE SHALL BE NO ELECTRICAL DISCONTINUITY DURING THE TEST.
1547 NO LAMP IN THE TEST CIRCUIT SHALL LIGHT.
ITEM(S) SHALL REMAIN WITHIN SPECIFIED TOLERANCE.
6277
TESTING SHALL BE PERFORMED IN ACCORDANCE WITH
6250 ACCELERATION.
THE BASE DOCUMENT, EXCEPT 6250.
49