DOD-STD-35-117(MI)
16 June 1978
CHAR
STANDARD PARAGRAPH
CODE
THE PRESSURE UNIT OF MEASURE FOR THE OPERATING
1732
CHARACTERISTICS SHALL BE MILLIMETERS OF MERCURY.
THE PRESSURE UNIT OF MEASURE FOR THE OPERATING
1734
CHARACTERISTICS SHALL BE MILLIMETERS OF MERCURY,
DIFFERENTIAL.
1749 THE SWITCH SHALL BE EQUIPPED WITH A PRESSURE RELIEF DEVICE
CAPABLE OF RELIEVING AN INTERNAL CASE DIFFERENTIAL PRESSURE,
RELATIVE TO THE ATMOSPHERE, OF 1740 POUNDS PER SQUARE INCH.
THE SWITCH SHALL BE EQUIPPED WITH A PRESSURE RELIEF DEVICE
1742
CAPABLE OF RELIEVING AN INTERNAL CASE DIFFERENTIAL PRESSURE.
RELATIVE TO THE ATMOSPHERE, OF 1742 PASCALS.
1744 THE SWITCH SHALL BE EQUIPPED WITH A PRESSURE RELIEF DEVICE
CAPABLE OF RELIEVING AN INTERNAL CASE DIFFERENTIAL PRESSURE,
RELATIVE TO THE ATMOSPHERE, OF 1744 KILOPASCALS.
PERFORMANCE.
THE MECHANICAL LIFE OF THE SWITCH SHALL BE NOT LESS THAN
1700
1700 CYCLES.
1702 THE ELECTRICAL LIFE OF THE SWITCH SHALL BE NOT LESS THAN
1702 CYCLES.