DOD-STD-35-117(MI)
16 June 1978
CHAR
CODE
STANDARD
PARAGRAPH
THERE SHALL BE NO EVIDENCE
TEMPERATURE, HIGH.
6229
OF PHYSICAL DAMAGE.
ITEM(S) SHALL REMAIN WITHIN SPECIFIED TOLERANCES.
2158
TESTING SHALL BE PERFORMED IN
TEMPERATURE, HIGH.
6217
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 6217.
TESTING SHALL BE PERFORMED IN
TEMPERATURE, HIGH.
6218
ACCORDANCE WITH METHOD 501 OF MIL-STD-811.
PROCEDURE NUMBER 6219 SHALL APPLY.
6219
STORAGE TEMPERATURE SHALL BE 6220 DEGREES CELSIUS.
6220
STORAGE DURATION SHALL BE 6221 HOURS.
6221
HIGHEST OPERATING TEMPERATURE SHALL BE 6222 DEGREES CELSIUS.
6222
6224 OPERATING TIME SHALL BE 6224 MINUTE(S).
6225
OPERATING TIME SHALL BE 6225 HOUR(S).
2150 THE LOAD SHALL BE 2150 PERCENT OF RATED LOAD.
THE LOAD TYPE SHALL BE 2152.
2152
2154 THERE SHALL BE 2154 OPERATING CYCLES.
137