DOD-STD-35-117(MI)
16 June 1978
CHAR
CODE
STANDARD
PARAGRAPH
4711 THERE SHALL BE NO DISCONTINUITY DURING THE TEST.
2354 THE DISCONTINUITY SHALL BE NOT GREATER THAN 2354
MICROSECONDS.
1896 THE DISCONTINUITY SHALL BE NOT GREATER THAN 1896
MILLISECONDS.
TESTING SHALL BE PERFORMED IN
1502 SHOCK, SPECIFIED PULSE.
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1502.
TESTING SHALL BE PERFORMED IN
1500 SHOCK, SPECIFIED PULSE.
ACCORDANCE WITH METHOD 213 OF MIL-STD202.
1504 TEST CONDITION LETTER 1504 SHALL APPLY.
4684 MOUNTING SHALL BE IN ACCORDANCE WITH 4684.
4685 MOUNTING SHALL BE BY THE NORMAL METHOD.
4686 MOUNTING SHALL BE BY ANY SUITABLE METHOD.