DOD-STD-35-85A(MI)
1 December 1978
CHAR
CODE
STANDARD
PARAGRAPH
THERE SHALL BE NO EVIDENCE OF
SHOCK, SPECIFIED PULSE.
1509
PHYSICAL DAMAGE.
4703
ITEM(S) SHALL REMAIN WITHIN SPECIFIED TOLERANCE.
MEASUREMENTS BEFORE TEST SHALL BE AS FOLLOWS.
2517 SPEED WITH LOAD SHALL BE 2517 REVOLUTIONS PER MINUTE.
2519 SPEED WITHOUT LOAD SHALL BE 2519 REVOLUTIONS PER MINUTE.
THE INSULATION RESISTANCE SHALL BE NOT LESS THAN 2521
2521
MEGOHM(S).
MEASUREMENTS AFTER TEST SHALL BE AS FOLLOWS.
2523 SPEED WITH LOAD SHALL BE 2523 REVOLUTIONS PER MINUTE.
2525 SPEED WITHOUT LOAD SHALL BE 2525 REVOLUTIONS PER MINUTE.
2527 THE INSULATION RESISTANCE SHALL BE NOT LESS THAN 2527
MEGOHM(S).
TESTING SHALL BE PERFORMED IN
SHOCK, SPECIFIED PULSE.
1502
ACCORDANCE WITH THE BASE DOCUMENT EXCEPT 1502.
93