DOD-STD-35-85A(MI)
1 December 1978
CHAR
CODE
STANDARD
PARAGRAPH
TESTING SHALL BE PERFORMED IN ACCORDANCE WITH
7311
SHOCK.
THE BASE DOCUMENT, EXCEPT 7311.
TESTING SHALL BE PERFORMED IN ACCORDANCE WITH
7312
SHOCK.
METHOD 516 OF MIL-STD-810.
7313 PROCEDURE NUMBER I SHALL APPLY.
7317 THE SHOCK PULSE SHAPE SHALL BE SAWTOOTH IN ACCORDANCE
WITH FIGURE 516-1 OF METHOD 516 OR MILSTD-810.
7318
THE SHOCK PULSE SHAPE SHALL BE HALF SINE WAVE IN
ACCORDANCE WITH FIGURE 516-2 OF METHOD 516 OF MIL-STD-810.
7305 AMPLITUDE LETTER 7305 SHALL APPLY.
7306 DURATION LETTER 7306 SHALL APPLY.
6327 PROCEDURE NUMBER II SHALL APPLY.
6338 PROCEDURE NUMBER III SHALL APPLY.
6344 THE SHOCK PULSE SHAPE SHALL BE SAWTOOTH IN ACCORDANCE
WITH FIGURE 516-1 OF METHOD 5116 OF MIL-STD810.
6345 THE SHOCK PULSE SHAPE SHALL BE HALF SINE WAVE IN ACCORDANCE
WITH FIGURE 516-2 OF METHOD 5116 OF MIL-STD-81.
6346 AMPLITUDE LETTER 6346 SHALL APPLY.
6347 DURATION LETTER 6347 SHALL APPLY.