DOD-STD-35-85A(MI)
1 December 1978
CHAR
CODE
STANDARD
PARAGRAPH
THE REQUIREMENT(S) SHALL BE IN
1435
VIBRATION, RANDOM.
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 3435.
1436
VIBRATION, RANDOM.
THERE SHALL BE NO EVIDENCE OF
PHYSICAL DAMAGE.
1538 ITEM(S) SHALL REMAIN WITHIN SPECIFIED TOLERANCE.
TESTING SHALL BE PERFORMED IN
1426
Vibration RANDOM.
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1426.
TESTING SHALL BE PERFORMED IN
1427
VIBRATION, RANDOM.
ACCORDANCE WITH METHOD 214 OF MIL-STD-202.
1428 TEST CONDITION NUMBER AND LETTER 1428 SHALL APPLY.
1438 THE DURATION OF THE TEST SHALL BE 3438 MINUTE(S).
1431 THE DURATION OF THE TEST SHALL BE 3431 HOUR(S).
1452 THE MONITORING INSTRUMENTATION OF THE VIBRATION
EXCITATION SHALL BE ANY SUITABLE INSTRUMENTATION SYSTEM.
1453 THE MONITORING INSTRUMENTATION OF THE VIBRATION
EXCITATION SHALL BE A CALIBRATED AC TO DC CONVERTER AND
STRIP CHART RECORDER.
1459 THE MONITORING INSTRUMENTATION OF THE VIBRATION
EXCITATION SHALL BE A CALIBRATED OSCILLOSCOPE.