DOD-STD-35-71A(MI)
14 January 1983
CHAR
CODE
STANDARD
PARAGRAPH
4734
SEAL.
TESTING SHALL BE PERFORMED IN ACCORDANCE WITH THE
BASE DOCUMENT, EXCEPT 4734.
4732
SEAL.
TESTING SHALL BE PERFORMED IN ACCORDANCE WITH METHOD
112 OF MILSTD202.
4737 TEST CONDITION LETTER A SHALL APPLY.
4-738 LIQUID FOR BUBBLE TEST BATH SHALL BE 4738.
4739 TEMPERATURE OF THE BUBBLE TEST BATH LIQUID SHALL BE NOT
LESS THAN 4739 DEGREES CELSIUS.
6320
TEST CONDITION LETTER B SHALL APPLY.
6321 LIQUID FOR BUBBLE TEST BATH SHALL BE 6321.
6322
TEMPERATURE OF THE BUBBLE TEST BATH LIQUID SHALL BE NOT
LESS THAN 6322 DEGREES CELSIUS.
6323
TEST CONDITION LETTER C SHALL APPLY.
4741 LEAK SENSITIVITY RATE SHALL BE 4741 ATM CC/SEC.
4740 PROCEDURE NUMBER I SHALL APPLY.