DOD-STD-35-71A(MI)
14 January 1983
CHAR
STANDARD PARAGRAPH
CODE
THE SOURCEOBJECT DISTANCE (THE DISTANCE FROM THE FOCAL
6285
SPOT OF THE XRAY TUBE TO THE OBJECT BEING RADIOGRAPHED)
SHALL BE 6285 INCH(S).
6287 THE VIEWING EQUIPMENT SHALL BE 6287.
6288 THE IMAGES SHALL BE VIEWED AT 6288 XPOWER MAGNIFICATION.
6289
THE DEFECTS TO BE SOUGHT SHALL BE 6289.
6284 NONFILM TECHNIQUES MAY BE USED, IF DESIRED, RECORDS
SHALL BE MAINTAINED, FOR EXAMINATION OR DELIVERY, AS
SPECIFIED.
TO FURTHER INSURE ADEQUATE QUALITY, A RADIOGRAPH OF THE
6283
PENETRAMETER SHALL BE INCLUDED ON EACH RADIOGRAPHIC FILM.
THE PENETRAMETER SHALL BE MADE FROM A SAMPLE ITEM OF THE
SAME TYPE AS THE ITEM BEING INSPECTED (RADIOGRAPHED).
THE PENETRAMETER SHOULD UTILIZE AN AWG SIZE 6263 COPPER
WIRE ON THE SIDE OF THE ITEM FARTHEST FROM THE XRAY FILM.
5297 TO FURTHER INSURE ADEQUATE QUALITY, A RADIOGRAPH OF THE
PENETRAMETER SHALL BE INCLUDED ON EACH RADIOGRAPHIC FILM.
THE PENETRAMETER SHALL BE MADE FROM A SAMPLE ITEM OF THE
SAME TYPE AS THE ITEM BEING INSPECTED (RADIOGRAPHED).
THE PENETRAMETER SHOULD UTILIZE A 5297 MILLIMETER(S)
DIAMETER COPPER WIRE ON THE SIDE OF THE ITEM FARTHEST
FROM THE XRAY FILM.
103
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business