DOD-STD-35-37A(MI)
15 December 1978
CHAR
CODE STANDARD PARAGRAPH
THERE SHALL BE NO EVIDENCE OF
1 3 9 6 MOISTURE RESISTANCE.
CORROSION OR PHYSICAL DAMAGE.
ITEM(S) SHALL REMAIN WITHIN SPECIFIED TOLERANCE.
1398
1394 THERE SHALL BE NO EVIDENCE OF FLASHOVER, MECHANICAL
DAMAGE, ARCING OR INSULATION BREAKDOWN, WHEN DIELECTRIC
WITHSTANDING VOLTAGE IS APPLIED.
1429 CURRENT LEAKAGE SHALL BE NOT GREATER THAN 1429
MILLIAMPERE(S) AT HIGH HUMIDITY.
1404 CURRENT LEAKAGE SHALL BE NOT GREATER THAN 1404
MILLIAMPERE(S) AFTER DRYING.
1432
INSULATION RESISTANCE SHALL BE NOT LESS THAN 1432
MEGOHM(S) AT HIGH HUMIDITY.
INSULATION RESISTANCE SHALL BE NOT LESS THAN 1406
1406
MEGOHM(S) AFTER DRYING.
TESTING SHALL BE PERFORMED IN
1 3 9 1 MOISTURE RESISTANCE.
ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1391.
TESTING SHALL BE PERFORMED IN
1 3 9 7 MOISTURE RESISTANCE.
ACCORDANCE WITH METHOD 106 OF MIL-STD-202.