DOD-STD-35-37A(MI)
15 December 1978
CHAR
CODE STANDARD PARAGRAPH
TESTING SHALL BE PERFORMED IN ACCORDANCE WITH
4809 IMMERSION.
THE BASE DOCUMENT, EXCEPT 4809.
4810 IMMERSION.
TESTING SHALL BE PERFORMED IN ACCORDANCE WITH
M E T H O D 104 OF MILSTD-202.
4 8 1 1 TEST CONDITION LETTER 4811 SHALL APPLY.
4 8 1 2 FINAL MEASUREMENT(S) SHALL BE MADE WITHIN 4812 HOUR(S)
AFTER FINAL CYCLE.
4814 MEASUREMENTS SHALL BE NOT MADE UNTIL 4814 HOUR(S) AFTER
THE FINAL CYCLE.
INCREMENTAL CURRENT INDUCTANCE REDUCTION.
2415
THE
REQUIREMENT(S) SHALL BE IN ACCORDANCE WITH THE BASE
DOCUMENT, EXCEPT 2415.
INCREMENTAL CURRENT INDUCTANCE REDUCTION*
2416
THE
INCREMENTAL CURRENT INDUCTANCE REDUCTION VALUE SHALL
REPRESENT A REDUCTION OF 2416 PERCENT.
2417 INCREMENTAL CURRENT INDUCTANCE REDUCTION.
THE
INCREMENTAL CURRENT INDUCTANCE REDUCTION VALUE SHALL
BE LESS THAN THE INDUCTANCE MEASURED WITH ZERO DC CURRENT.
73