DOD-STD-35-138(MI)
5 January 1979
CHAR
CODE
STANDARD
PARAGRAPH
1490 THERE SHALL BE NO DISCONTINUITY DURING TEST.
2900 DISCONTINUITY SHALL BE NOT GREATER THAN 2900
Microsecond
2902 DISCONTINUITY SHALL BE NOT GREATER THAN 2902
MILLISECOND(S).
1553 NO LAMP IN THE TEST CIRCUIT SHALL LIGHT.
TESTING SHALL BE PERFORMED
VIBRATION, LOW FREQUENCY.
1466
IN ACCORDANCE WITH THE BASE DOCUMENT, EXCEPT 1466.
TESTINS SHALL BE PERFORMED
VIBRATION, LOW FREQUENCY*
1467
IN ACCORDANCE WITH METHOD 201 OF MIL-STD-202.
1470 DURATION OF TEST SHALL BE 1470 HOUR(S) PER AXIS.
4731 MOUNTING SHALL BE BY ANY SUITABLE METHOD.
4730 MOUNTING SHALL BE BY THE NORMAL METHOD.
4729 MOUNTING SHALL BE IN ACCORDANCE WITH 4729.
1535
THE DIRECTION OF MOTION SHALL BE PARALLEL TO THE
LONGITUDINAL AXIS,
1536 THE DIRECTION OF MOTION SHALL BE PERPENDICULAR TO THE
LONGITUDINAL AXIS.